-----  Resonance/ELMAVAN WF analysis  -----
-- Generated on Thu Apr 11 23:50:34 2019 --
-------------------------------------------
 
   Source: 001__elm20190411_214242__dat00.bin
   3D WAVEFORMS (Measured data  sampled at 50 kHz) 50999 packets of 144 samples from 2019-04-11T21:42:43.390.000.
   Median difference of the 200-kHz counter in neigbouring packets:             576
   Expected difference of the 200-kHz counter for continuous data :             576

   SRAM used (0-7):   0  1  2  3  4  5  6  7
   SRAM address increments:  -32767      1      2

   WF capture start time: 2019-04-11T21:42:43.390.000
   Number of continuous data intervals: 2
   List of continuous data intervals (DI): 
   DI No.  Duration (ms)  Packets   Gap to the next (ms)  Aver. 1 (TMU)  Aver. 2 (TMU)  Aver. 3 (TMU)  Aver. 4 (TMU)  Aver. 5 (TMU)  Aver. 6 (TMU)  Aver. 7 (TMU)  SDev. 1 (TMU)  SDev. 2 (TMU)  SDev. 3 (TMU)  SDev. 4 (TMU)  SDev. 5 (TMU)  SDev. 6 (TMU)  SDev. 7 (TMU)
        0      96920.641    33653                  2.880         -8.649        -14.701        -19.481          0.000          0.000          0.000          0.000         12.792         10.839         13.146          0.000          0.000          0.000          0.000

     0 -3900 -2704 -5572     0     0     0     0  3173  1827  4934     0     0     0
     0
        1      49956.480    17346                  0.000         -8.668        -14.700        -19.550          0.000          0.000          0.000          0.000         13.794         10.361         15.817          0.000          0.000          0.000          0.000

     1 -5567 -1488 -9273     0     0     0     0  6803  1343  7406     0     0     0
     0

   No SRAM CRC errors found. 